HomeProductsSkillairBitNew Deal E-Mail
Skillair

     The superior technology of Skillair® FRL units is the expression of Metal Work innovation. The FRL system is the brainchild of a joint study by Metal Work engineers and researchers from the Department of Mechanics in Turin. The integration of metal alloys and super-resistant techno-polymers is the result of co-operation between CESAP(European Center for the Development of Plastic Applications) and leading international companies such as Du Pont, EMS Chemie and Hoechst. The installation of advanced processing and quality control systems guarantees the reliability of Skillair® FRLs.
Technical features
The Skillair units incorporate very interesting technological features:
  • Compactness – with the same flow capacity our unit is one of the smallest on the market.
  • Modularity – various elements such as filters, reducers, lubricators, 3-way valves, progressive actuators and air take-offs can be combined at will.
    With the modular system the FRL units can be removed without disturbing the pipes.
  • Easy maintenance – Any of the elements or the entire unit can be removed without disturbing the remaining part or pipes.
TECHNICAL DATA SK 100 SK 100 SK 200 SK 200 SK 200 SK 300 SK 300 SK 300 SK 400 SK
400
SK
400
SK
400
Threaded port 1/4" 3/8" 1/4" 3/8" 1/2" 1/2" 3/4" 1" 1" 1"1/4" 1"1/2" 2"
Degree of filtration
Degree of purification
5µm 20µm 50µm
99.97% to 0.01µm
Setting range bar 0÷2 0÷4 0÷8 0÷12
Max. input pressure Mpa
bar
psi
1.5
15
217
1.3
13
188
1.3
13
188
1.3
13
188
Flow rate at 6 bar (0.6 MPa-87 psi)
P 0,5 bar (0,05MPa ÷ 7 psi)
From 1100 to

20000 NI/min

Fluid Lubricated or unlubricated compressed air
Temperature range at 1 MPa; 10 bar; 145 psi °C
°F
10° ÷+50°
14 °÷122°
Elements comprising the range Filter, Depurator, Regulator, Pilot operated regulator, In-series Regulator, Filter-regulator, Lubricator with various lubricant filling systems, Circuit Shut-off Valve, Progressive Actuator.
SKILLAIR MODULARITY
The FRL units can be removed from the system without disturbing the pipes. This can be done with a single element or with the entire system. Assemble the unit so that the air flows in the direction marked by the arrows.