Manually-operated circuit shut-off valve.
In this position you can extract the shim and fit a lock to avoid accidental operation. |
![]() |
| TECHNICAL DATA | V3V ND 1/4 | V3V ND 3/8-1/2 | |
| Threaded port | 1/4 | 3/8 - 1/2 | |
| Max. inlet pressure | MPa bar psi |
1.8 18 261 |
|
| Flow rate at 6 bar (0.6 MPaś87 psi) |
Nl/min scfm |
1100 38.8 |
2200 78 |
| Flow rate at 6 bar (0.6 MPaś87 psi) |
Nl/min scfm |
1500 53 |
2900 103 |
| Flow rate on relieving at 6 bar (0.6 MPaś87 psi) | 1600 | 2900 | |
| Direct rilieving into the atmosphere | 56.5 | 103 | |
| Fluid | Filtered, lubricated or unlubricated compressed air; Lubrication, if used, must be continuous | ||
| Max temperature at 1 MPa; 10 bar; 145 psi | °C °F |
50 122 |
50 122 |
| Weight | Kg | 0.35 | 0.8 |
| Wall fixing screws | M4x40 | M4x55 | |
| Mounting | In any position | ||
| Type of control | Manual | ||
| COMPONENTS | |
|
![]() |